This project has moved. For the latest updates, please go here.
1

Closed

ZigBee : AtCommand ctor does not allow to set register?

description

I think that public constructor "public AtCommand(string command, byte[] value)" misses in its implemetation of following assignment: "this.Value = value;".
 
Without it every AT command that tries to set a register fails, since it is given back the current register value.
 
Same issue arises even when using AtRemoteCommand's ctors that use the aforementioned ATCommand ctor.
 
I suspect that another issue could arise in CheckFrame() method of XBee class, since it does'n manage correctly responses about Api types other than AtCommandResponse (i.e AtRemoteCommandResponse or ZigBeeTransmitStatus).
Closed Nov 8, 2010 at 11:46 AM by interactive

comments

wrote Nov 8, 2010 at 11:46 AM

Resolved with changeset 59005.

wrote Feb 14, 2013 at 7:10 PM

wrote May 16, 2013 at 8:49 AM